Publication

Ship Borne Direct Eddy Covariance Flux Measurements

Landwehr, Sebastian Johannes Heinz-Josef
Citation
Abstract
Ship borne direct eddy covariance flux measurements of momentum, heat (latent and sensible), and the trace gas CO2, were conducted during three open ocean experiments. The methods for data analysis and interpretation were adapted from the literature, and reviewed carefully. Two major sources of measurement errors were studied in detail: the air-flow distortion by the platform superstructure and the cross-sensitivity of the CO2 signal to water vapour. For both topics a revision of the treatment, as suggested in the literature, was found necessary. Air-flow distortion can lead to a tilt of the wind vector as well as acceleration of the wind speed. Eddy covariance measurements are additionally affected by the platform motion. The classic approach is to first correct for the platform motion and thereafter rotate the wind vector into the mean flow. For moving ships, this causes an over-estimation of the tilt, because the flow distortion-induced vertical velocity is proportional to the relative wind speed. The overestimated tilt leads to biased flux estimates. This may explain the common observation that flux estimates from moving ships have lower quality than measurements taken on station. An alternative method is presented here, where the flow distortion-induced tilt is estimated from the wind speed measurements and applied after correcting for the platform motion, but before removing the ship's mean velocity. This significantly reduced the flow distortion error in the direct flux measurements. With respect to CO2, the flux measurements are affected by cross-sensitivities to water vapour, resulting in order-of-magnitude biases. Well established cause are (i) band-broadening and spectral overlap, and (ii) air density fluctuations. Both can be corrected. A further bias related to humidity fluctuations has recently been observed with the widely used CO2/H2O open-path sensors produced by LICOR, attributed to sea salt build-up and water films on the sensor optics. Two different approaches have been used: Miller et al. (2010) employed a membrane drier to physically eliminate 97% of the water vapour fluctuations in the sample air before it entered a closed-path gas analyser. Prytherch et al. (2010a) formulated the PKT (Peter K. Taylor) post-processing correction. Here these methods are compared using four closed-path analysers, two of which were positioned down-stream of membrane dryers. The CO2 fluxes from the dried analysers matched each other and were in general agreement with common parameterisations. The measurements from the un-dried sensors agreed only when the humidity flux was low and exhibited order-of magnitude biases otherwise. The PKT correction did not remove the bias. The results demonstrate the validity of measuring CO2 fluxes at pre-dried air and disprove the PKT correction.
Publisher
Publisher DOI
Rights
Attribution-NonCommercial-NoDerivs 3.0 Ireland