Multi-laboratory validation study of multilocus variable-number tandem repeat analysis (mlva) forsalmonella entericaserovar enteritidis, 2015
Peters, Tansy ; Bertrand, Sophie ; Björkman, Jonas T ; Brandal, Lin T ; Brown, Derek J ; Erdõsi, Tímea ; Heck, Max ; Ibrahem, Salha ; Johansson, Karin ; Kornschober, Christian ... show 10 more
Peters, Tansy
Bertrand, Sophie
Björkman, Jonas T
Brandal, Lin T
Brown, Derek J
Erdõsi, Tímea
Heck, Max
Ibrahem, Salha
Johansson, Karin
Kornschober, Christian
Publication Date
2017-03-02
Type
Article
Downloads
Citation
Peters, Tansy; Bertrand, Sophie; Björkman, Jonas T; Brandal, Lin T; Brown, Derek J; Erdõsi, Tímea; Heck, Max; Ibrahem, Salha; Johansson, Karin; Kornschober, Christian; Kotila, Saara M; Le Hello, Simon; Lienemann, Taru; Mattheus, Wesley; Nielsen, Eva Møller; Ragimbeau, Catherine; Rumore, Jillian; Sabol, Ashley; Torpdahl, Mia; Trees, Eija; Tuohy, Alma; de Pinna, Elizabeth (2017). Multi-laboratory validation study of multilocus variable-number tandem repeat analysis (mlva) forsalmonella entericaserovar enteritidis, 2015. Eurosurveillance 22 (9), 13-20
Abstract
Multilocus variable-number tandem repeat analysis (MLVA) is a rapid and reproducible typing method that is an important tool for investigation, as well as detection, of national and multinational outbreaks of a range of food-borne pathogens. Salmonella enterica serovar Enteritidis is the most common Salmonella serovar associated with human salmonellosis in the European Union/European Economic Area and North America. Fourteen laboratories from 13 countries in Europe and North America participated in a validation study for MLVA of S. Enteritidis targeting five loci. Following normalisation of fragment sizes using a set of reference strains, a blinded set of 24 strains with known allele sizes was analysed by each participant. The S. Enteritidis 5-loci MLVA protocol was shown to produce internationally comparable results as more than 90% of the participants reported less than 5% discrepant MLVA profiles. All 14 participating laboratories performed well, even those where experience with this typing method was limited. The raw fragment length data were consistent throughout, and the interlaboratory validation helped to standardise the conversion of raw data to repeat numbers with at least two countries updating their internal procedures. However, differences in assigned MLVA profiles remain between well-established protocols and should be taken into account when exchanging data.
Funder
Publisher
European Centre for Disease Control and Prevention (ECDC)
Publisher DOI
Rights
Attribution-NonCommercial-NoDerivs 3.0 Ireland